Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone Joint J ; 106-B(5): 435-441, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688480

RESUMO

Aims: Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods: Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results: Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion: At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Prótese de Quadril , Humanos , Masculino , Feminino , Estudos Prospectivos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Medidas de Resultados Relatados pelo Paciente , Idoso de 80 Anos ou mais , Polimetil Metacrilato
2.
Clin Orthop Relat Res ; 481(9): 1689-1699, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37104550

RESUMO

BACKGROUND: The Exeter® stem is used worldwide, often in older patients, and it is the second most commonly used cemented stem design in Sweden. Previous studies have shown that for cemented stems with a composite beam, the smallest sizes result in an increased risk of revision for mechanical failure. However, little is known about whether the survivorship of the polished Exeter stem, which generally has been shown to be good, might be associated with design parameters such as stem dimensions or offset at extreme implant sizes. QUESTION/PURPOSE: Are differences in (1) stem size or (2) offset of the standard Exeter V40 150-mm stem associated with differences in the risk of stem revision for aseptic loosening? METHODS: Between 2001 and 2020, 47,161 Exeter stems were reported to the Swedish Arthroplasty Register, with very high coverage and completeness documented during the period studied. In this cohort, we included patients with primary osteoarthritis who underwent surgery with a standard Exeter stem length of 150 mm and V40 cone with any type of cemented cups that had had at least 1000 reported insertions. This selection resulted in a study cohort representing 79% (37,619 of 47,161) of the total number of Exeter stems in the registry during that time. The primary study outcome was stem revision for aseptic indications such as loosening, periprosthetic fracture, dislocation, and implant fracture. A Cox regression was performed, with adjustment for age, gender, surgical approach, year of surgery, use of highly crosslinked polyethylene cups, and femoral head size and length dictated by the shape of the head trunnion. Adjusted hazard ratios are presented with 95% confidence intervals. Two separate analyses were performed. The first analysis excluded stems with the highest offsets (50 mm and 56 mm, which were not available for stem size 0). The second analysis excluded stem size 0 to include all offsets. Because stem survival was not proportional over time, we divided the analyses into two insertion periods, 0 to 8 years and beyond 8 years. RESULTS: Stem size 0 (compared to size 1) was associated with an increased risk of revision up to 8 years when all stem sizes were included (first analysis 0 to 8 years, HR 1.7 [95% CI 1.2 to 2.3]; p = 0.002). Forty-four percent (63 of 144) of revisions of size 0 stems were for periprosthetic fracture. There was no consistent association between stem size and risk of aseptic stem revision when size 0 was excluded in the second analysis beyond 8 years. The most common offset (44 mm) was associated with an increased risk of revision (compared with 37.5 mm) up to 8 years when all sizes were included (first analysis, HR 1.6 [95% CI 1.1 to 2.1]; p = 0.01). In the second analysis (beyond 8 years, all offsets included), offset of 44 mm was compared with offset of 37.5 mm; compared with the first period, this offset was associated with a reduced risk (HR 0.6 [95% CI 0.4 to 0.9]; p = 0.005). CONCLUSION: We found overall high survival of the Exeter stem, with generally little or no influence of stem variations on the risk of aseptic revision. However, stem size 0 was associated with an increased risk of revision mainly for periprosthetic fractures. If the femoral anatomy offers a choice between sizes 0 and 1 in patients with poor bone quality who are at risk of periprosthetic fracture, our data speak in favor of choosing the larger stem if the surgeon believes it is safe to insert the larger size, or, if available, another stem design that has a documented lower risk of this complication. For patients with good cortical bone quality but very narrow canals, a cementless stem may also be a good alternative. LEVEL OF EVIDENCE: Level III, therapeutic study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Suécia , Fraturas Periprotéticas/cirurgia , Falha de Prótese , Reoperação/efeitos adversos , Desenho de Prótese , Sistema de Registros , Fatores de Risco
3.
Hip Int ; 33(5): 872-879, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36314413

RESUMO

BACKGROUND: Elevated serum chrome (sCr) and cobalt (sCo) concentrations are associated with local tissue adverse reactions to metal debris following metal-on-metal hip resurfacing (MoM-HR). Serum metal ions <2 µg/l are probably of little clinical relevance and a pragmatic "safe" threshold <5 µg/l has been suggested.The primary aim of this study was to evaluate if a careful selection of patients combined with optimal implant positioning could eliminate cases with "unsafe" serum metal ion levels. A secondary aim was to study the association between different risk factors and having Co and/or Cr levels >5 µg/l. PATIENTS AND METHODS: This is a retrospective, single-institution cohort study of 410 consecutive patients operated on with a Birmingham Hip Resurfacing (BHR) implant between 2001 and 2014. 288 of these had a unilateral MoM-HR, pelvic and true lateral radiographs, and a related sCo and sCr sample, and were included in the final analysis. They were allocated to either a presumed "optimal group" consisting of only men aged <60 years old, with femoral head component >48 mm diameter, and with a cup positioned within Lewinnek's safe zones, or a "suboptimal group" consisting of the remaining patients. Fisher's exact test and multiple logistic regression analyses were performed. RESULTS: In the optimal group 48% (47/97) had serum metal ions >2 µg/l and 8% (8/97) >5 µg/l compared to 61% (116/191) and 18% (34/191) in the suboptimal group, p = 0.059 and p = 0.034 respectively. Acetabular cups with an anteversion <5 degrees had the highest odds ratio, 6.5 (95% CI, 3.0-14.3), of having sCo and sCr concentrations exceeding 5 µg/l. CONCLUSIONS: A well oriented BHR acetabular component in a presumably "optimal" patient reduces the risk of having elevated serum metal ions but does not eliminate it. Insufficient cup anteversion seems to be the strongest associated factor of elevated serum metals.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Masculino , Humanos , Pessoa de Meia-Idade , Cobalto , Artroplastia de Quadril/efeitos adversos , Seleção de Pacientes , Estudos de Coortes , Estudos Retrospectivos , Próteses Articulares Metal-Metal/efeitos adversos , Cromo , Metais , Prótese de Quadril/efeitos adversos , Íons , Desenho de Prótese
4.
Acta Orthop ; 93: 459-465, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35478261

RESUMO

BACKGROUND AND PURPOSE: Computed tomography micromotion analysis (CTMA) can be used to determine implant micro-movements using low-dose CT scans. By using CTMA, a non-invasive measurement of joint implant movement is enabled. We evaluated the precision of CTMA in measuring early cup migration. Standard marker-based radiostereometric analysis (RSA) was used as reference. We hypothesised that CTMA can be used as an alternative to RSA in assessing implant micromotions. PATIENTS AND METHODS: We included 30 patients undergoing total hip arthroplasty (THA). Acetabular cup migration at 1 year was measured with RSA and CTMA. To determine the precision of both methods, 20 double examinations (postoperatively) with repositioning of the patients were performed. The precision was calculated from zero by assuming that there was no motion of the prosthesis between the 2 examinations. RESULTS: The precision of RSA ranged from 0.06 to 0.15 mm for translations and 0.21° to 0.63° for rotations. Corresponding values for CTMA were 0.06 to 0.13 mm and 0.23° to 0.35°. A good level of agreement was found between the methods regarding cup migration and rotation at 1 year. INTERPRETATION: The precision of CTMA in measuring acetabular cup migration and rotation is comparable to marker-based RSA. CTMA could possibly thus be used as an alternative method to detect early implant migration.


Assuntos
Artroplastia de Quadril , Análise Radioestereométrica , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Humanos , Estudos Prospectivos , Análise Radioestereométrica/métodos , Tomografia Computadorizada por Raios X
5.
Acta Orthop ; 93: 37-42, 2022 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-34633905

RESUMO

Background and purpose - Almost all prosthetic implant brands include several variations. Most studies on implant performance investigate an implant system without sub-analysis of implant attributes. We studied the influence of design variations during the last 2 decades on implant survival of the most frequently used cemented femoral stem, the Lubinus SPII, reported to the Swedish Arthroplasty Register (SHAR). Patients and methods - Between 2000 and 2018, 100,032 cemented Lubinus SP II stems had been reported to SHAR. Patients with primary osteoarthritis operated on with stem length 150 mm together with a cemented cup from the same manufacturer (n = 76,530) were included in this analysis. Primary study outcome was non-infectious stem revision. Cox regression with adjustment for age, sex, surgical approach, and year of surgery was used. Hazard rates (HR) are presented with 95% confidence intervals (CI). Results - Average follow-up was 7.6 years (SD 4.2). At 18 years the overall stem survival was 99.1 (CI 98.9-99.3). Increased revision rate was observed for stems with extra offset, when a long or an extra-long head length had been used. Smaller stem sizes, in particular the smallest stem size (01), substantially increased the rate of mechanical failure as reflected by an almost 10 times increased rate of revision compared with the standard size (2). Interpretation - In this study with larger sample size and longer follow-up than previously presented from the same register, we observed more pronounced effects of previously documented design variations. Based on our results, surgeons using the Lubinus SPII stems are advised to consider an alternative solution if a Lubinus stem size 01, Lubinus extra offset, or an extra-long head seems to be the most suitable choice at the preoperative planning.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Idoso , Cimentos Ósseos , Feminino , Humanos , Masculino , Sistema de Registros , Suécia
6.
Hip Int ; 24(4): 355-62, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24817401

RESUMO

During the first decade of the 21st century, metal-on-metal hip resurfacing became one of the main treatment options for younger, more active patients with osteoarthritis. However, as a result of the reported failure rate of both total hip replacement (THR) and resurfacing in patients with considerable loss of bone stock in the femoral head (e.g., in extensive avascular necrosis), other solutions have been sought for these patients. The short-stemmed Birmingham Mid Head Resection prosthesis (BMHR) combines a metal-on-metal articulation and a femoral neck preserving feature. In this study, radiostereometric analysis (RSA) was used to study migration of the BMHR femoral component in 13 hips. Translations and rotations were measured up to two years. Relative values showed no statistically significant migration. Absolute values demonstrated settling in occurring between zero and two months postoperatively in all directions studied. From two months to two years no significant migration occurred except for rotation around the x-axis of the femoral segment (p = 0.049). After initial settling-in, absolute values were low, indicating that there was no evidence of early migration or loosening of the components.


Assuntos
Artroplastia de Quadril/métodos , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Análise Radioestereométrica/métodos , Adulto , Feminino , Cabeça do Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...